GENERAL TECHNICAL DATA
IQL 04 | IQL 06 | |||
Force (Max) | [KN] | 4 | 6 | |
Stroke (Max) | [mm] | 40 | 40 | |
Positioning speed | 0.7 / 0.83 mm/sec (50/60Hz) | 0.7/ 0.90 mm/sec (50/60Hz) | ||
Manual override | Handwheel with switchable declutchable lever | |||
Enclosure EN60529 | IP66 | |||
Cable entry | 2 – PF 3/4” TAP | |||
Position indicator | Gradulation on pillar pointed by carrier plate | |||
Housing | Aluminum alloy hard anodized for anti-corrosion | |||
Painting | Epoxy powder coated | |||
Ambient temperature | [C°] | -20°C ~ +70°C | ||
Operating mode IEC34-1, 8 | S2 30 Min S24 1200 c/h 50%ED | |||
Weight | [Kgs] | 9 | 9 |
ACTUATOR SPEED AND ELECTRIC DATA
Rated Current (A) | 1 Phase | 3 Phase | AC/DC | |||||||
110VAC | 220VAC | 380VAC | 440VAC | |||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 24V | ||
IQL 04 | 0.45 | 0.44 | 0.26 | 0.25 | 0.3 | 0.31 | 0.28 | 0.40 | 3.0 | |
IQL 06 | 0.49 | 0.48 | 0.29 | 0.28 | 0.32 | 0.33 | 0.30 | 0.42 | 3.5 | |
Motor protection | Thermal switch, Class F insulation | |||||||||
Space heater | 5 W (110/220VAC) for anti condensation | |||||||||
Limit switch | 1 each for open/close (SPDT 10A 250VAC rating) |
VALVE MOUNTING
Valve stem threads | mm | M20 (Max) | M20 (Max) |
PCD on flange | mm | 100 | 100 |
Pillar Threads | M16 | M16 | |
Mounting direction | Any direction except for heading downward | ||
Pillar material | Non corrosive material |