GENERAL TECHNICAL DATA
IQL 08 | IQL 10 | IQL 12 | ||
Force (Max) | [KN] | 8 | 10 | 12 |
Stroke (Max) | [mm] | 50 | 50 | 50 |
Positioning speed | 0.7 / 0.8 mm/sec (50/60Hz) | 0.7 / 0.8 mm/sec (50/60Hz) | 0.7 / 0.8mm/sec (50/60Hz) | |
Manual Override | Handwheel with switchable declutchable lever | |||
Enclosure EN60529 | IP66 | |||
Cable entry | 22 – PF ¾” TAP | |||
Position indication | Gradulation on pillar pointed by carrier plate | |||
Housing | Aluminum alloy hard anodized for anti-corrosion | |||
Painting | Epoxy powder coated | |||
Ambient temperature | [°C] | -20°C ~ +70 °C | ||
Operating mode IEC34-1,8 | S2 30 Min S4 1200 c/h 50%ED | |||
Weight | [Kgs] | 18 | 18 | 18 |
ACTUATOR SPEED AND ELECTRIC DATA
Rated Current (A) | 1 Phase | 3 Phase | AC/DC | |||||||||
110VAC | 220VAC | 380VAC | 440VAC | |||||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 24V | ||||
IQL 08 | 0.92 | 0.88 | 0.48 | 0.46 | 0.18 | 0.17 | 0.17 | 0.16 | 2.90 | |||
IQL 10 | 0.95 | 0.91 | 0.50 | 0.48 | 0.19 | 0.18 | 0.18 | 0.17 | 3.20 | |||
IQL 12 | 0.98 | 0.94 | 0.52 | 0.50 | 0.20 | 0.19 | 0.19 | 0.18 | 3.50 | |||
Motor protection | Thermal switch, Class F insulation | |||||||||||
Space heater | 5 W (110/220VAC) for anti condensation | |||||||||||
Limit switch | 2 each for open/close (SPDT 10A 250VAC rating) | |||||||||||
Force switch | 1 each for open//close (SPDT 10A 250VAC rating) |
VALVE MOUNTING
Valve stem threads | mm | M20 (Max) | M20 (Max) |
PCD on flange | mm | 100 | 100 |
Pillar Threads | M16 | M16 | |
Mounting direction | Any direction except for heading downward | ||
Pillar material | Stainless steel, carbon steel with special surface treatment |