GENERAL TECHNICAL DATA
IQL 04 | IQL 06 | |||
Force (Max) | [KN] | 20 | 25 | |
Stroke (Max) | [mm] | 100 | 100 | |
Positioning speed | 0.85/1.1 mm/sec (50/60Hz) | 0.85/1.1 mm/sec (50/60Hz) | ||
Manual override | Handwheel with switchable declutchable lever | |||
Enclosure EN60529 | IP66 | |||
Cable entry | 2 – PF 3/4” TAP | |||
Position indicator | Gradulation on pillar pointed by carrier plate | |||
Housing | Aluminum alloy hard anodized for anti-corrosion | |||
Painting | Epoxy powder coated | |||
Ambient temperature | [C°] | -20°C ~ +70°C | ||
Operating mode IEC34-1, 8 | S2 30 Min S24 1200 c/h 50%ED | |||
Weight | [Kgs] | 23 | 24 |
ACTUATOR SPEED AND ELECTRIC DATA
Rated Current (A) | 1 Phase | 3 Phase | AC/DC | |||||||
110VAC | 220VAC | 380VAC | 440VAC | |||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 24V | ||
IQL 20 | 1.75 | 1.68 | 0.93 | 0.89 | 0.3 | 0.3 | 0.32 | 0.31 | 6.0 | |
IQL 25 | 1.8 | 1.72 | 0.95 | 0.92 | 0.32 | 0.34 | 0.33 | 7.0 | 7.0 | |
Motor protection | Thermal switch, Class F insulation | |||||||||
Space heater | 5 W (110/220VAC) for anti condensation | |||||||||
Limit switch | 2 each for open/close (SPDT 10A 250VAC rating) | |||||||||
Force switch | 1 each for open/close (SPDT 10A 250VAC rating) |
VALVE MOUNTING
Valve stem threads | mm | M20 (Max) | M20 (Max) |
PCD on flange | mm | 165 | 165 |
Pillar Threads | M20 | M20 | |
Mounting direction | Any direction except for heading downward | ||
Pillar material | Stainless steel, carbon steel with special surface treatment |